Use this dialog to specify data that should be transmitted as response to incoming data.
![]() |
Response Data dialog |
Use this field to specify a trigger response trigger. When the specified trigger is encountered in any received data, the ports respond by sending the data specified in the 'Send data' field.
Use this field to specify data that should be sent when the specified trigger is received.
Check this field to activate the current trigger when the port is idle.
Check this field to activate the current trigger when the port status is 'receiving'.
Check this field to activate the current trigger when the port status is 'send'.
Use this field to specify the response delay. If a response delay is specified, DNC-Max waits the specified time before sending the response.
![]() | No other data will be sent while until the time has elapsed. |
Check this field if DNC-Max should clear the XOff status, and send response data even if an XOff has been received.