Advanced settings dialog |
Check this field to ignore sub-program call inside comments.
Check this field if DNC-Max should ignore calls to non-existing sub-programs.
![]() | The line containing the call is not removed from the transmitted data. |
Check this field to scan inserted sub-programs for nested sub-program calls.
![]() | Any direct or in-direct recursions will cause DNC-Max to abort the transfer. |
Check this field if DNC-Max should look for the requested start line/block number or tool change after inserting sub programs.
Check this field to use a repeat trigger.
When using a repeat trigger, DNC-Max will insert the sub-program as many times as specified after the repeat trigger.
Use this field to specify the repeat trigger.
DNC-Max will use the numerical value following the specified triggers, as the sub-program repeat count.
Example: If the repeat triggers is 'L', and the sub-program call line is 'N1010 M98 1234 L17', the sub-program 1234 is repeated 17 times.
Use this field to specify the minimum number of times that a sub-program should be repeated.
Use this field to specify the maximum number of times that a sub-program can be repeated. A value of 0 specifies that a sub-program can be repeated an unlimited number of times.
Use this field to specify the start trigger used in sub-programs.
Ignore start trigger: Do not use any start trigger when scanning sub-programs. The entire sub-program file is inserted.
Use transmit start trigger: Use start trigger specified at the 'Send at start of feed' setup sheet (if any).
Use specified start trigger: Use the start trigger specified below.
Use this field to specify the start trigger.
Use this field to specify how the trigger line should be sent.
Check this field to ignore start triggers inside comments, or after block skips.
Use this field to specify the end trigger used in sub-programs.
Ignore end trigger: Do not use any end trigger when scanning sub-programs. The entire sub-program file is inserted.
Use transmit end trigger: Use end trigger specified at the 'Send at end of feed' setup sheet (if any).
Use specified end trigger: Use the end trigger specified below.
Use this field to specify an end trigger.
If the control is configured to send a new line character after the DPRNT command, then you should specify a new line (\LF or \CR) in this field.
Use this field to specify how the trigger line should be saved.
Check this field to ignore end triggers inside comments, or after block skips.